Occasionally a MegaRAID or SAS controller volume will list the drive members as 'Unconfigured foreign' or 'Unconfigured Bad', and the volume will be inaccessible. It is possible to recover the volume and keep the data intact using MSM (MegaRAID Storage Manager) or the WebBIOS.

**Applies To**  
LSI MegaRAID and LSI SAS controllers. 

**Steps**  
1. Reboot the system
2. Go into LSI WebBIOS by pressing CTRL+H at boot time when prompted.
3. Click on a 'Unconfigured Bad' drive from front screen of WebBIOS
4. On the next screen, you will see an option to make 'Unconfigured good'. Select that option and click GO. Do not select any other option(s).
5. Repeat for all drive(s) in the volume.
6. Now you are back on the front page.
7. Click Scan Devices. It will ask you if you want to import the foreign configuration. Select Preview, if looks right, then go ahead and import the configuration.
8. Reboot and the volume and its data should be accessible.

If the array does not import, call LSI storage support or create an online support ticket.  