title: vSAN over RDMA Thor enablement
url: https://www.broadcom.com/vsan-over-rdma-thor-enablement
description: vSAN over RDMA Thor enablement
---

# vSAN over RDMA Thor enablement

## Solution

**Symptoms**:

On a ESXi7.0 & 6.7 system, links on a BCM57508 & BCM57504 adapter may go down after collecting vm-support logs on the system. Messages such as these can be seen in the vmkernel log:

```
+++++++++++++++++++++++
2021-11-25T08:22:59.882Z cpu44:2431755)WARNING: bnxtnet: hwrm_get_version:2483: [vmnic4 : 0x452089304000] VER_GET failed- FW_STATUS_REG: 0x88100
2021-11-25T08:22:59.882Z cpu44:2431755)WARNING: bnxtnet: hwrm_snd_fw_msg:543: [vmnic4 : 0x452089304000] Looks like FW is crashed. Dumping FW trace and reporting link down to OS
2021-11-25T08:22:59.885Z cpu44:2431755)WARNING: bnxtnet: dev_dump_fw_trace:152: [vmnic4 : 0x452089304000] Dumping FW Trace:
2021-11-25T08:22:59.885Z cpu44:2431755)bnxtnet: dev_print_fw_data:123: [vmnic4 : 0x452089304000] == START OF TRACE ==
2021-11-25T08:22:59.885Z cpu44:2431755)bnxtnet: dev_print_fw_data:135: [vmnic4 : 0x452089304000] == END OF TRACE ==
2021-11-25T08:22:59.885Z cpu44:2431755)WARNING: bnxtnet: dev_dump_fw_trace:162: [vmnic4 : 0x452089304000] Dumping RoCE FW Trace:
2021-11-25T08:22:59.885Z cpu44:2431755)bnxtnet: dev_print_fw_data:123: [vmnic4 : 0x452089304000] == START OF TRACE ==
2021-11-25T08:22:59.885Z cpu44:2431755)bnxtnet: dev_print_fw_data:135: [vmnic4 : 0x452089304000] == END OF TRACE ==
2021-11-25T08:22:59.885Z cpu44:2431755)bnxtnet: bnxtnet_report_link_down_to_uplink:1487: [vmnic4 : 0x452089304000] Reporting Link down
+++++++++++++++++++++++
```

**Cause**:

This happens because of an issue in bnxtnet driver 221.0.84.0 & earlier.

**Resolution**:

This issue will be fixed in a future version of bnxtnet driver. Currently if the issue occurs, the system needs to be rebooted for the BCM5750x adapter links to become operational.

**Workaround**:

Two possible workarounds:

1. While collecting vm-support logs skip the Hardware section with ‘vm-support -e Hardware:base’.
2. Bring all links of the BCM5750x NIC down with ‘esxcli network nic down -n \<vmnicX\>’ before collecting vm-support logs.